KT Trilink
A cobalt-chromium coping is the metal substructure of a porcelain-fused-to-metal (PFM) crown. Made from medical-grade cobalt-chromium alloy using precision lost-wax casting or CAD/CAM milling, it provides a strong foundation for the veneering porcelain.
Outsource coping fabrication:
Dental labs can order the metal coping separately and handle porcelain veneering, shade matching, and custom contouring in-house.
Verify full seating and confirm that the margins meet the prescription on the working model. This helps identify fit or margin issues before porcelain application.
When clearance to the opposing teeth is limited, confirm how much space to allocate to the metal coping and veneering porcelain before fabrication.
Confirm the required surface finish, areas where metal will remain exposed, and any further surface preparation needed for the receiving lab’s veneering workflow.
Tensile Strength
Vickers Hardness
Marginal Gap
| Item | Product Description |
| Product Name | CoCr Coping for PFM Crowns |
| Material | Medical-grade cobalt-chromium (Co-Cr) alloy |
| Main Alloying Elements | Approx. 60% cobalt (Co), 25% chromium (Cr), and 5% molybdenum (Mo) |
| Tensile Strength | ≥ 800 MPa |
| Yield Strength | ≥ 550 MPa |
| Vickers Hardness | ≥ 350 HV |
| Elongation | ≥ 6% |
| Density | Approx. 8.3 g/cm³ |
| Coefficient of Thermal Expansion (CTE) | (13.5–14.5) × 10⁻⁶ K⁻¹ |
| Fabrication Methods | Precision lost-wax casting or CAD/CAM milling |
| Minimum Thickness | Margin ≥ 0.3 mm, occlusal surface ≥ 0.5 mm |
| Alloy Composition and Compliance | Nickel-free and beryllium-free. Meets ISO 22674 requirements. |
Tooth-supported PFM single crowns — A Co-Cr coping can serve as the metal substructure when the clinician selects a cobalt-chromium porcelain-fused-to-metal (PFM) restoration and the tooth preparation, margin location, and available restorative space meet the requirements of the selected system.
Cement-retained implant-supported PFM single crowns — Once the clinician selects the abutment, the coping can be made to fit its contours if the materials and restorative design permit. Confirm with the lab before placing the order.
PFM fixed bridges — When indicated, order a CoCr Framework for PFM Bridges and confirm the bridge span, connector requirements, and material limitations separately. Use bridge-specific specifications for these cases.
What is the difference between a CoCr Coping for PFM Crowns and a finished CoCr PFM crown?
A CoCr Coping for PFM Crowns is the cobalt-chromium substructure supplied before porcelain veneering. The receiving dental lab can apply the porcelain, match the shade, and shape the final contours in-house.
A CoCr PFM crown is the finished porcelain-fused-to-metal restoration. It combines the cobalt-chromium coping with a porcelain veneer that provides the intended tooth shade and external contours.
The difference is what the lab receives. The CoCr Coping for PFM Crowns is supplied as an unveneered metal substructure for dental labs that prefer to apply porcelain in-house. A CoCr PFM crown is delivered as a fully veneered restoration with the final shade, contours, and occlusal anatomy, ready for clinical try-in.
What are the advantages of the CoCr Coping for PFM Crowns over a zirconia coping?
The CoCr Coping for PFM Crowns provides rigid support for veneering porcelain and fits into established porcelain-fused-to-metal (PFM) workflows. Labs can order the coping separately and apply the porcelain in-house. The metal substructure can be designed to leave room for veneering porcelain while meeting the alloy system’s minimum thickness requirements.
A zirconia coping may be preferred when anterior translucency, avoiding a metal undertone, or a metal-free restoration is a priority. The minimum thickness for either coping depends on the specific material system.
Can the lab verify space for veneering porcelain from a scan of the prepared tooth alone?
A scan of the prepared tooth shows the preparation contours and finish line. The lab also needs an opposing arch scan and a bite record to determine whether there is enough occlusal or incisal clearance for both the CoCr Coping for PFM Crowns and the veneering porcelain.
When ordering, submit a scan of the working arch that includes the prepared tooth and adjacent teeth, an opposing arch scan, and a bite record. If the lab finds insufficient clearance during design, it will contact the clinic or lab that submitted the case before fabrication.
What does the lab check before shipping a CoCr Coping for PFM Crowns?
The lab checks seating on the working model, marginal fit, clearance for veneering porcelain, and metal surface quality. The coping should seat fully without rocking, with continuous margins and no visible gaps. The lab uses the opposing arch records and bite record to verify that the coping leaves enough space for porcelain veneering, then checks the metal surface for burrs, sharp edges, and visible porosity.
Before packing, the lab verifies the case ID, tooth number, and order details to confirm that the shipment contains the unveneered metal coping.